Tracker Cells Production

Below a list of all the cassettes produced in Manchester. Click on the cassette name to get more details.


List of C0 cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment Quality Flag MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C0-001/002)
SNCM_000 2013-Apr-26 test unknown DISMANTLED Produced in unclean environment BAD N/A N/A N/A N/A
SNCM_001 2013-Aug-20 test short/big DISMANTLED nylon cord used to tie up the internal harness GOOD N/A N/A N/A N/A
SNCM_002 2013-Oct-09 production long/small DISMANTLED 3 cathode pins on the far end broken (cells 4, 7 and 12) GOOD N/A N/A N/A N/A
SNCM_003 2013-Oct-22 production short/big DISMANTLED Returned to UoM for dismantling. GOOD PTFE ties. REJECTED due to discoloration of copper rings (DW 03/04/14). 18/03/14 N/A N/A
SNCM_004 2013-Nov-28 production long/small DISMANTLED cells 01, 12 & 13 with bad plateau BAD N/A N/A N/A N/A
SNCM_005 2013-Dec-19 production long/small LSM few noisy cells (1-5 Hz): 00, 01, 07, 09 and 13 GOOD PTFE ties. Int. harness partly re-routed on 01/05/14. Cassette frame cleanliness - medium. Three particles on the wires. Two green copper rings. Cleaned before inspection. 18/03/14 13/05/14 C0-040/041
SNCM_006 2014-Jan-16 production short/big LSM noisy cell13 probably due to faulty HV channel GOOD PTFE ties. Int. harness partly re-routed on 01/05/14. One of the cleanest frames so far. One particle found on the wires, 2 copper rings have green patches. Cleaned before insertion into frame. 18/03/14 13/05/14 C0-042/043
SNCM_007 2014-Feb-03 production long/small DISMANTLED piece of dust removed from cell13 GOOD PTFE ties. OK to install in C0 (DW 03/04/14) Int. harness partly re-routed on 01/05/14. REJECTED following cleaning under UV lamp because 8 particles could not be removed from (cathode) wires. They appear to be burnt on. (RS and DW 23/6/14). Also anode wire broken at female connector end (not cell end). This could be repaired and is not the reason why the cassette has been rejected. 18/03/14 N/A N/A
SNCM_008 2014-Feb-22 production short/big LSM very long conditioning GOOD PTFE ties. Int. harness partly re-routed on 01/05/14. Inspected under U.V. at MSSL. 17 particles found on inside of cassette and 4 sizeable particles on wires. PTFE heat shrink (internal harness)covered in dust. Cleaned before insertion into frame. 30/04/14 01/05/14 C0-054/055
SNCM_009 2014-Feb-26 production long/small LSM self-triggering point in cells 04 - 11 and 16 GOOD Some PTFE ties used. Copper wire ties also fitted from this cassette onwards. OK to install in C0 (DW 03/04/14) Int. harness re-routed on 01/05/14. Frame dirty like SNCM_008, two particles on wires, 1 copper ring slightly green and end caps dirty. Cleaned before insertion into frame. 18/03/14 13/05/14 C0-044/045
SNCM_010 2014-Mar-24 production short/big LSM conditioned with normal and reverse polarity (except cell02) GOOD Int. harness re-routed on 01/05/14. Inspected under U.V. at MSSL on 09/05/14, 1 particle on wire, particles on heat-shrink (internal harness), cassette better than SNCM-008. Cleaned with nitrogen to remove particles before insertion. NOTE: Broken crimp on anode on top end cap in column and broken crimp on ground wire in other top end cap - Manc to bring crimp tools and repair ! 30/04/14 09/05/14 C0-050/051
SNCM_011 2014-Mar-27 production long/small LSM conditioned with normal and reverse polarity GOOD Int. harness re-routed on 01/05/14. Cassette inspected under U.V. at MSSL on 09/05/14 - cassette frame cleanliness bad like SNCM-008. A loose screw was found rolling around inside the cassette (not from the cassette). No significant particles found on tracker wires. Again cells cleaned before insertion. 30/04/14 09/05/14 C0-048/049
SNCM_012 2014-Apr-15 production short/big LSM fluff removed from cell01 GOOD New internal harness routing done at Manc from this cassette onwards. Inspected under U.V. at MSSL on 9/5/14, 2 particles on wire (1 fell from cassette onto wire). Cells cleaned with nitrogen to remove particles before insertion. 30/04/14 09/05/14 C0-046/047
SNCM_013 2014-Apr-24 production long/small LSM self-trig points in cell 03, 09, 10, 11 GOOD Inspected under U.V. torch at MSSL on 01/05/14 - cleaner than SNCM_008. Cleaned before insertion into frame. 30/04/14 01/05/14 C0-052/053
SNCM_014 2014-May-01 production long/small DISMANTLED rejected due to plasma blocks on cells 01, 03, 09 of unknown origin BAD N/A N/A N/A N/A
SNCM_015 2014-May-08 production short/big LSM all good GOOD Inspected under UV lamp. Some particles found inside cassette, lots stuck to PTFE sleeving, but none on the wires. 20/06/14 23/06/14 C0-038/039
SNCM_016 2014-May-28 production short/big LSM all good GOOD Inspected under UV lamp, three loose particles were removed from the wires using N2 flushing. A few particles remain on the copper cathode rings and PTFE heatshrink. Internal harness to cell 08 broken at start of cell insertion. Cassette removed, repaired and tested by Dave and Michele before being inserted into C0 (24/6/14). Connection to top cell on anode and cathode side broken (14/7/14). 20/06/14 24/06/14 C0-030/031
SNCM_017 2014-Jun-03 production long/small LSM all good GOOD Cleanest cassette yet - no particles on the wires, little in the cassette, only a few particles on the PTFE heat shrink. No connections broken (23/6/14). Connection to top cell on cathode side broken (14/7/14) 20/06/14 23/06/14 C0-036/037
SNCM_018 2014-Jun-05 production short/big LSM all good (cell09 anode wire replaced) GOOD No particles on the wires, only a few on the PTFE heat shrink and inside the cassette. 20/06/14 24/06/14 C0-034/035
SNCM_019 2014-Jun-10 production long/small LSM all good GOOD No particles on the wires, only a few on the PTFE heat shrink and inside the cassette. 20/06/14 24/06/14 C0-032/033
SNCM_020 2014-Jun-17 production short/big LSM all good GOOD Cleanliness good. No dust particles. 10/07/14 27/08/14 C0-022/023
SNCM_021 2014-Jun-20 production long/small LSM all good GOOD Particles could not be removed from copper cathode ring of cell 07 during cleaning. Ground wire broken on cell 15 (not harness). Not sure when this occurred. Cassette not installed.

Update 19/8/14 : Julian successfully replaced the broken wire. There were 4 or 5 breakages of the internal cable harness connections to the cells that will need to be fixed. Also there is still some stubborn contamination on the end-caps that we will need to see if we can remove prior to insertion. If these problems can be solved, then this cassette can be installed.

10/07/14 08/10/14 C0-004/005
SNCM_022 2014-Jun-25 production short/big LSM all good (cells 12 + 13 anode wire replaced) GOOD One breakage on ground chain on top cell of cathode side. 10/07/14 14/07/14 C0-026/027
SNCM_023 2014-Jun-26 production short/big LSM all good GOOD Miscabling on internal harness found. Socket for cell 04 inserted into a vacant pin on female connector (anode end). Corrected. Broken pin on anode end. 10/07/14 27/08/14 C0-018/019
SNCM_024 2014-Jul-03 production long/small LSM all good GOOD No particles left on wires. Top cell on anode side broken. 10/07/14 14/07/14 C0-028/029
SNCM_025 2014-Jul-09 production long/small DISMANTLED kinks blocking plasma on cells 1 & 2 BAD N/A N/A N/A N/A
SNCM_026 2014-Jul-17 production long/small LSM all good GOOD Particle could not be removed from tracker wire of cell (4th row from foil). Internal harness broken on top cell (anode end). Could not do up 4th screw on feedthrough. 19/08/14 26/08/14 C0-024/025
SNCM_027 2014-Jul-21 production long/small LSM all good GOOD 1-2 particles removed from wire and copper ring. 19/08/14 27/08/14 C0-020/021
SNCM_028 2014-Jul-25 production long/small LSM all good GOOD Particles cleaned from copper rings and PTFE harness. 19/08/14 05/09/14 C0-016/017
SNCM_029 2014-Jul-31 production long/small LSM all good GOOD One stubborn particle on one of the field wires, managed to remove it eventually. 19/08/14 05/09/14 C0-012/013
SNCM_030 2014-Aug-07 production short/big LSM cell 10 with self trigger, improving over time GOOD As well as the usual cleaning, a big particle was removed from the anode wire. 19/08/14 05/09/14 C0-014/015
SNCM_031 2014-Aug-12 production long/small LSM all good GOOD Only a few particles found and removed. 07/10/14 08/10/14 C0-008/009
SNCM_032 2014-Aug-14 production short/big LSM all good GOOD 1-2 particles removed with nitrogen 07/10/14 08/10/14 C0-010/011
SNCM_033 2014-Aug-19 production short/big LSM all good GOOD Only a few particles removed. 07/10/14 08/10/14 C0-006/007
SNCM_034 2014-Sep-02 production long/small LSM all good GOOD Some particles found on the copper rings and removed. Cell note: Chamfers cut on outside corner of cells 08 & 17 to help with last insertion into bottom cell support frame. OM Note: Corner of mylar patch has peeled off on front (tracker) face of X-wall OM in column 14 closest to source (0865). No repair attempted as likely to cause further damage. 07/10/14 10/10/14 C0-000/001
SNCM_035 2014-Sep-04 production short/big DISMANTLED strong self-triggering point on cells 1 & 15 BAD N/A N/A N/A N/A
SNCM_036 2014-Sep-25 production short/big LSM all good GOOD A big piece of fluff was removed from the wires. 07/10/14 10/10/14 C0-002/003


List of C1 cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment Quality Flag MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C1-001/002)
SNCM_037 2014-Oct-07 production long/small LSM all good GOOD Exceptionally clean all over including harness. Broken harness wire. (Repaired 14/5/15 - details TBC). 03/12/14 12/03/15 C1-063/064
SNCM_038 2014-Oct-29 production long/small LSM all ok. Re-configured to the special rotated C0 cassette. GOOD Two bits of fluff removed from the wires. Tricky to install, as limited access and the corner of the bottom two cells had not been chamfered. 30/04/15 14/05/15 C1-057/058
SNCM_039 2014-Nov-05 production short/big LSM ok GOOD No particles found on wires. One anode wire broken at anode end (cell 0). (Repaired 14/5/15.) A two part delrin clamp pin was found inside the cassette and removed. It had not been used on the cells, as the two parts were not pushed together. It had most likely fallen off the wiring robot and bounced into the cassette whilst at Manchester. 03/12/14 12/03/15 C1-059/060
SNCM_040 2014-Nov-11 production long/small LSM ok GOOD Nothing on the wires. Some particles found inside the cassette. All removed. 03/12/14 12/03/15 C1-067/068
SNCM_041 2014-Nov-18 production short/big LSM ok GOOD Reasonably clean but one speck found on wire and removed. One anode wire broken at anode end (cell 0).(Repaired 14/5/15.) Copper tube fell into C1 during repair (not retrieved/found). 03/12/14 12/03/15 C1-061/062
SNCM_042 2014-Nov-26 production long/small LSM ok GOOD One speck removed from the wire. Harness looked good. 11/02/15 13/03/15 C1-071/072
SNCM_043 2014-Dec-03 production short/big LSM cell 11 noisy GOOD Three particles found on the wires, one fluffy and 1mm in size. All removed. 11/02/15 12/03/15 C1-065/066
SNCM_044 2014-Dec-09 production long/small DISMANTLED 2 bad cells BAD N/A N/A N/A N/A
SNCM_045 2014-Dec-12 production short/big LSM all ok GOOD The cathode crimp on cell 17 (cathode end) was broken and had to be repaired before it could be inserted into C1. Also, the ground wire on cell 11 (cathode end) was not crimped the copper tab. 11/02/15 16/03/15 C1-073/074
SNCM_046 2015-Jan-07 production short/big DISMANTLED too many bad cells BAD N/A N/A N/A N/A
SNCM_047 2015-Jan-15 production long/small LSM short plateau on cell01 GOOD Tracker cathode wire broken half way down stack (anode end) during cell insertion. Tracker wire cut off at both ends and removed to stop it wrapping around the other tracker wires. Decided at tracker meeting on 14/4/15 to leave cassette in C1 and not replace missing wire. 11/02/15 16/03/15 C1-075/076
SNCM_048 2015-Jan-27 production short/big LSM repair on HV bar cell03; self-triggering point in cell05 GOOD Cleanliness ok. One speck of dust found on wire, which was removed. However the harness was very untidy. (1) At the anode end, two of the cathode wires were not tied into the bundle which makes them vunerable to damage. (2) The two cathode bundles at the anode end were threaded through eachother, before entering the two connectors, and could not be separated. (3) The wires, which go to the cathode bus bars on cells 8 and 17 were bent downwards, instead of upwards, and would have touched the inside of the lower gas seal plate and ultimately the source foil, when C1 was installed at the LSM. These connections have therefore been pushed back up. 11/02/15 13/03/15 C1-069/070
SNCM_049 2015-Feb-17 production short/big LSM small self-triggering point in cell11 GOOD All ok, except for one speck that could not be removed from one of the tracker ground wires. 18/03/15 28/04/15 C1-077/078
SNCM_050 2015-Feb-20 production long/small LSM missing ground wire in cell 09 GOOD Cleanliness ok. One speck removed. 18/03/15 28/04/15 C1-079/080
SNCM_051 2015-Feb-24 production long/small LSM cell06 has short plateau GOOD Clean. 18/03/15 28/04/15 C1-083/084
SNCM_052 2015-Feb-27 production short/big LSM ok GOOD Two bits of fluff removed. 18/03/15 28/04/15 C1-081/082
SNCM_053 2015-Mar-05 production long/small LSM all ok GOOD 2 specks removed from the tracker wires. 30/04/15 14/05/15 C1-087/088
SNCM_054 2015-Mar-19 production short/big LSM all ok GOOD 1 speck removed with nitrogen. 30/04/15 14/05/15 C1-085/086
SNCM_055 2015-Mar-23 production long/small LSM all ok GOOD 2 specks removed from the tracker wires. Some variation in cable length, one of which was quite short. Adjusted copper cable tie locations to partially compensate. 30/04/15 14/05/15 C1-091/092
SNCM_056 2015-Mar-25 production short/big LSM small self-triggering point in cell 08 GOOD 4 specks removed from the tracker wires with nitrogen. 30/04/15 14/05/15 C1-089/090
SNCM_057 2015-Mar-27 production long/small LSM all ok GOOD A hair and a speck of dirt were removed from the internal harness(anode end) and one speck was removed from a tracker wire. Two patches of grease (1cm diameter) were found on the inside of the cassette (on the small side panel on the opposite side to the cassette label). 20/05/15 29/05/15 C1-095/096
SNCM_058 2015-Apr-02 production short/big LSM self-triggering point in cell 03 GOOD Pretty clean. Only one speck had to be removed from the wires. 20/05/15 29/05/15 C1-093/094
SNCM_059 2015-Apr-16 production short/big LSM all ok GOOD Clean, but had one spot of grease (1cm diameter) again on the inside of the cassette (on the small side panel on the opposite side to the cassette label). 20/05/15 29/05/15 C1-097/098
SNCM_060 2015-May-01 production long/small LSM all ok GOOD Clean 20/05/15 29/05/15 C1-099/100
SNCM_061 2015-May-12 production short/big LSM small self-triggering point on cell 05 GOOD One big speck on the wire. 20/05/15 29/05/15 C1-101/102
SNCM_062 2015-May-14 production long/small LSM all good, passed straight away GOOD Cleanliness very good. 11/06/15 18/06/15 C1-103/104
SNCM_063 2015-May-18 production short/big LSM cell 01 narrowish plateau GOOD Cleanliness good. One spec found on wire. 11/06/15 18/06/15 C1-105/106
SNCM_064 2015-May-21 production long/small LSM cells 1 & 7 narrow plateau GOOD Cleanliness good. 11/06/15 18/06/15 C1-107/108
SNCM_065 2015-May-26 production short/big LSM self-triggering point on cell 03 GOOD Cleanliness good. One spec found on wire. 11/06/15 18/06/15 C1-109/110
SNCM_066 2015-Jun-02 production long/small LSM all ok GOOD Cleanliness good. 11/06/15 18/06/15 C1-111/112


List of C2 cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment Quality Flag MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C2-001/002)
SNCM_067 2015-Jun-09 production long/small MSSL short plateau cell 5 GOOD One speck removed.Ground wires are too short, so future repairs may be difficult/impossible due to a lack of excess wire. 06/08/15 22/09/15 C2-048/049
SNCM_068 2015-Jun-11 production short/big MSSL all ok GOOD Anode wire broke on cell 3, so was sent back to Manchester on 23/9/15. Also at least one harness break at cathode end, which happened when the cassette was removed. Anode wire replaced by Manchester and multiple breakages in the internal harness to cell 0 and cell 1 also repaired. Checked again, all ok.(SdC 26/9/15). To be sent back to MSSL on 4th C2 transport. (MJC 28/9/15) Three specks were removed from the wires. However, the cathode wire on cell 0(cathode end) broke on the crimp(not in the usual place)and will be difficult to repair in the confined space (MJC 13/11/15) 06/08/15 & redelivered on 05/11/15 13/11/15 C2-026/027
SNCM_069 2015-Jun-15 production short/big MSSL all ok GOOD One speck of dust removed. Internal harness broken at the cathode end in column 52 on cell 9 (broken crimp pin). 06/08/15 22/09/15 C2-052/053
SNCM_070 2015-Jul-01 production short/big MSSL all ok [but copper bars in the inner side] GOOD Four specks of dust on tracker wires and a long piece of hair shaped debris on anode copper ring under anode wire. Could not remove all debris on wire and had to use tweezers to get debris of copper ring. Cathode wire broke on cell 15 and has been cut and removed. Also broken cathode pin (anode end)on female connector. 06/08/15 22/09/15 C2-050/051
SNCM_071 2015-Jul-08 production long/small MSSL all ok [special C0 cassette] GOOD One speck of dust removed.Broken anode pin (cathode end) on female connector. 06/08/15 22/09/15 C2-054/055
SNCM_072 2015-Jul-22 production long/small MSSL all ok GOOD Cleanliness OK. 24/09/15 01/10/15 C2-044/045
SNCM_073 2015-Jul-24 production short/big MSSL all ok GOOD A kink was noticed in one of the field wires during cell inspection. This wire subsequently broke at this kink and had to be cut out. 24/09/15 01/10/15 C2-046/047
SNCM_074 2015-Jul-28 production long/small MSSL all ok GOOD Cleanliness OK. 24/09/15 01/10/15 C2-040/041
SNCM_075 2015-Jul-30 production short/big MSSL all ok GOOD Another field wire broke and had to be cut out. It is thought this was, most likely, caused by another kink in the wire, although this cannot be confirmed. 24/09/15 01/10/15 C2-042/043
SNCM_076 2015-Aug-05 production long/small MSSL plasma block in cell 2 GOOD A squashed delrin clamp pin was found inside two of the copper rings. Both were removed. The heatshrink around one of the cathode crimp pins has slid along the wire and no longer covers the crimp pin. There is also a bad kink in the harness, near the feedthrough end, and the delrin coating has become thin and transparent. It will need to be cut out and the harness repaired. 24/09/15 23/10/15 C2-036/037
SNCM_077 2015-Aug-18 production short/big MSSL all ok GOOD One speck removed from a tracker wire. 08/10/15 23/10/15 C2-038/039
SNCM_078 2015-Aug-20 production long/small MSSL all ok GOOD One speck removed from a tracker wire. Two pins came out of the big connector (anode end). Put back in but could be swapped over. 08/10/15 23/10/15 C2-032/033
SNCM_079 2015-Sep-02 production short/big MSSL cell 7 is bad GOOD A shiny strand of presumably metal could be seen dangling from one of the field wires. It could not be removed but could be slid along the wire, so was pushed into one of the end caps (cell 9 bottom left hand side). Four other specks found on the tracker wires were removed. A mark could be seen on the cathode ring of cell 0 (anode end). 08/10/15 23/10/15 C2-034/035
SNCM_080 2015-Sep-10 production long/small MSSL all ok GOOD Also very clean. Just one small speck removed from wire. 08/10/15 27/10/15 C2-028/029
SNCM_081 2015-Sep-15 production short/big MSSL all ok GOOD Cleanest cassette so far ! 08/10/15 27/10/15 C2-030/031
SNCM_082 2015-Sep-30 production long/small MSSL cell 6 is bad GOOD Three specks were removed from the wires. Cassette 82 later removed and reinserted (on 17/11/15) to replace misaligned frame 5 (with 1 repair on cell 14 cathode wire at cathode end). 05/11/15 13/11/15 C2-024/025
SNCM_083 2015-Oct-07 production short/big MSSL cell 1 is bad GOOD Two specks of dust removed from the wires with N2. Cassette 83 later removed and reinserted without damage (on 17/11/15) to replace misaligned frame 5. 05/11/15 13/11/15 C2-022/023
SNCM_084 2015-Oct-12 production long/small MSSL all ok GOOD Three specks of dust removed from the wires with N2. Cell 17 had no proper ground connection (180 ohm according to DVM) on the anode side. However, the cathode side was fine, so cells were inserted. Cassette 84 later removed and reinserted without damage (on 17/11/15) to replace misaligned frame 5. 05/11/15 13/11/15 C2-020/021
SNCM_085 2015-Oct-20 production short/big MSSL all ok GOOD Five specks of dust were removed from the wires with N2. Cassette 85 later removed and reinserted (on 17/11/15) to replace misaligned frame 5 (with 4 repairs, 1 at anode end and 3 at cathode end, 1 being a broken ground wire - all subsequently repaired). 05/11/15 13/11/15 C2-018/019
SNCM_086 2015-Oct-22 production long/small MSSL all ok GOOD Two specks found, one removed but the other one looks to be burnt onto the wire. 26/11/15 30/11/15 C2-016/017
SNCM_087 2015-Oct-27 production short/big MSSL cell 6 is bad GOOD No specks found. 26/11/15 30/11/15 C2-014/015
SNCM_088 2015-Oct-30 production long/small MSSL self-triggering point in cell 1 GOOD One speck removed from a wire. 26/11/15 30/11/15 C2-012/013
SNCM_089 2015-Nov-04 production short/big MSSL all ok GOOD One speck removed from a wire. 26/11/15 30/11/15 C2-010/011
SNCM_090 2015-Nov-06 production long/small MSSL self-triggering point in cell 7 GOOD No specks found. 26/11/15 30/11/15 C2-008/009
SNCM_091 2015-Nov-13 production short/big MSSL all ok GOOD Cleanliness good. 06/01/16 07/01/16 C2-002/003
SNCM_092 2015-Nov-19 production long/small MSSL cell 1 is bad GOOD One speck removed from a wire. Cassette went in easily. 06/01/16 07/01/16 C2-000/001
SNCM_093 2015-Nov-27 production short/big MSSL plasma blocking on cell 15; self-triggering point in cell 4 is improving with time GOOD One speck removed from the wire. A ground pin came out of the connector at the anode end and had to be re-inserted. 06/01/16 07/01/16 C2-006/007
SNCM_094 2015-Dec-02 production long/small UoM cell 15 is bad SPARE
SNCM_095 2015-Dec-14 production long/small MSSL cell 11 is bad GOOD Some specks removed from the copper rings. Cassette went in relatively easily. 06/01/16 07/01/16 C2-004/005


List of C3 cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment Quality Flag MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C2-001/002)
SNCM_096 2016-Jan-06 production short/big MSSL self-triggering point in cell 12 GOOD Two specks removed from the wires. 25/02/16 22/04/16 C3-057/058
SNCM_097 2016-Jan-28 production long/small MSSL self-triggering point in cell 14 GOOD Clean. 25/02/16 22/04/16 C3-059/060
SNCM_098 2016-Feb-03 production short/big MSSL all ok GOOD 5-6 specks of dust removed and 1cm wire removed from one of the ground wires. Multiple harness breakages repaired. Kinks on both two bottom anode wires and in exactly the same place i.e. quarter of the way from anode end(cells 8 and 17). 25/02/16 29/04/16 C3-069/070
SNCM_099 2016-Feb-08 production long/small MSSL all ok GOOD One ground wire under insufficient tension to remain taut, so removed from cell 10. 25/02/16 28/04/16 C3-063/064
SNCM_100 2016-Feb-11 production short/big MSSL all ok GOOD Repaired. Problem with crimps on internal harness. Dust removed from the wires and cathode rings. A 3cm long piece of tracker wire was also coiled around one of the ground wires and had to be removed with tweezers. 25/02/16 28/04/16 C3-065/066
SNCM_101 2016-Feb-16 production long/small MSSL all ok GOOD Ground wire broken on cell 16 and removed. Particle removed from anode wire with tweezers and four specks removed from tracker wires and cathode rings. Cell 12 (anode end) cathode harness wire repaired (broken during insertion) 27/04/16 29/04/16 C3-067/068
SNCM_102 2016-Feb-22 production short/big MSSL self-triggering point in cell 13; few cells with short (but >50 V) plateau GOOD Clean. 27/04/16 28/04/16 C3-061/062
SNCM_103 2016-Feb-26 production long/small MSSL all ok GOOD One speck only removed from wire. 27/04/16 29/04/16 C3-071/072
SNCM_104 2016-Mar-01 production short/big MSSL all ok GOOD Harness needed repair before cell insertion. Two specks removed from copper end rings. A piece of delrin removed one of the end caps. 27/04/16 29/04/16 C3-073/074
SNCM_105 2016-Mar-08 production long/small MSSL all ok GOOD Two specks removed from copper rings. Rest clean. 27/04/16 24/05/16 C3-075/076
SNCM_106 2016-Mar-15 production short/big MSSL all ok GOOD Clean. Just two specks removed from copper rings. 19/05/16 24/05/16 C3-077/078
SNCM_107 2016-Mar-17 production long/small MSSL small self-triggering point in cell 4 GOOD Broken ground crimp on cell 17(anode end) repaired. Two specks removed from end caps. 19/05/16 19/07/16 C3-095/096
SNCM_108 2016-Mar-23 production short/big MSSL ground loop A replaced on uninstrumented end GOOD Unable to remove mark from copper ring (cell 4 on cathode side). Part of a delrin clamp pin found and removed. 19/05/16 24/05/16 C3-081/082
SNCM_109 2016-May-03 production long/small MSSL self-triggering point in cell 11 GOOD Clean. Just two specks removed from copper rings. 19/05/16 24/05/16 C3-079/080
SNCM_110 2016-May-06 production short/big MSSL self-triggering point in cell 13 GOOD Clean. Plastic tie bar between lower two cathode clamp pins broken and sticking out. 12/07/16 19/07/16 C3-093/094
SNCM_111 2016-May-23 production long/small MSSL all ok GOOD Two specks removed from wires. 12/07/16 18/07/16 C3-083/084
SNCM_112 2016-May-25 production short/big MSSL all ok GOOD Clean. 12/07/16 18/07/16 C3-085/086
SNCM_113 2016-Jun-01 production long/small MSSL all ok GOOD Clean. 12/07/16 18/07/16 C3-087/088
SNCM_114 2016-Jun-14 production short/big MSSL minor self-triggering point in cell 1 & 6 GOOD One speck of dust removed from wire. One field wire removed from cell 13 (external side, bottom cathode wire) 12/07/16 18/07/16 C3-089/090
SNCM_115 2016-Jun-22 production long/small MSSL all ok GOOD Clean. 12/07/16 19/07/16 C3-091/092
SNCM_116 2016-Jul-05 production short/big MSSL self-triggering point in cell 05 GOOD One speck removed, otherwise clean. 09/08/16 23/08/16 C3-097/098
SNCM_117 2016-Jul-12 production long/small MSSL cell 3 is bad GOOD Clean. 09/08/16 23/08/16 C3-099/100
SNCM_118 2016-Jul-13 production short/big MSSL all ok GOOD Clean. 09/08/16 23/08/16 C3-101/102
SNCM_119 2016-Jul-27 production long/small MSSL plasma blocking in cell 12

(New PTFE batch)

GOOD One speck removed, otherwise clean. 09/08/16 30/08/16 C3-103/104
SNCM_120 2016-Jul-29 production short/big MSSL all ok

(New PTFE batch)

GOOD Clean. 09/08/16 30/08/16 C3-105/106
SNCM_121 2016-Aug-02 production long/small UoM self-triggering point in cell 12

(New PTFE batch)

GOOD Cleanliness good. 28/09/16 03/10/16 C3-111/112
SNCM_122 2016-Aug-10 production short/big UoM self-triggering point in cells 1, 2 & 9 and plasma blocking point in cell 2

(New PTFE batch)

GOOD Cleanliness good. 28/09/16 03/10/16 C3-109/110
SNCM_123 2016-Aug-12 production long/small UoM cell 05 anode wire missing

(New PTFE batch)

GOOD Cleanliness good. 28/09/16 03/10/16 C3-107/108


List of special cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment Quality Flag MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C2-001/002)
SNCM_C0C1 2016-Apr-01 production long/small LSM ground loop A replaced on uninstrumented end GOOD One dust particle removed from wire. Passed continuity check at MSSL. Delivered to LSM and installed. Post installation check showed that an anode crimp had come out at the veto top end (cathode end) and was re-crimped in situ. 27/04/16 11/08/16 C0C1-056
SNCM_C2C3 2016-Aug-30 production long/small UoM all ok

(New PTFE batch)

GOOD Cleanliness good. Passed continuity check at MSSL. Will be delivered to the LSM with the last C-section (C2). 28/09/16 TBD at LSM C2C3-056


List of spare cassettes

Cassette Name Date of Production Cassette Type Far-end Connector Current Location UoM Comment MSSL Comments Date of delivery to MSSL Date of installation C-section and column nos. (e.g. C2-001/002)
SNCM_094 2015-Dec-02 C1 or C2 long/small UoM cell 15 is bad


Cell ageing during production

Integrated charge [C] of all four C-sections:

Ageing.jpg


Click on the thumbnails to view a single C-section:

C0 Ageing.png C1 Ageing.png

C2 ageing.png C3 ageing.png


Tracker Layout

Side 0 Side 1
C2 000-001 C0 000-001
C2 002-003 C0 002-003
C2 004-005 C0 004-005
C2 006-007 C0 006-007
C2 008-009 C0 008-009
C2 010-011 C0 010-011
C2 012-013 C0 012-013
C2 014-015 C0 014-015
C2 016-017 C0 016-017
C2 018-019 C0 018-019
C2 020-021 C0 020-021
C2 022-023 C0 022-023
C2 024-025 C0 024-025
C2 026-027 C0 026-027
C2 028-029 C0 028-029
C2 030-031 C0 030-031
C2 032-033 C0 032-033
C2 034-035 C0 034-035
C2 036-037 C0 036-037
C2 038-039 C0 038-039
C2 040-041 C0 040-041
C2 042-043 C0 042-043
C2 044-045 C0 044-045
C2 046-047 C0 046-047
C2 048-049 C0 048-049
C2 050-051 C0 050-051
C2 052-053 C0 052-053
C2 054-055 C0 054-055
-------------------- --------------------
C3 057-058 C1 057-058
C3 059-060 C1 059-060
C3 061-062 C1 061-062
C3 063-064 C1 063-064
C3 065-066 C1 065-066
C3 067-068 C1 067-068
C3 069-070 C1 069-070
C3 071-072 C1 071-072
C3 073-074 C1 073-074
C3 075-076 C1 075-076
C3 077-078 C1 077-078
C3 079-080 C1 079-080
C3 081-082 C1 081-082
C3 083-084 C1 083-084
C3 085-086 C1 085-086
C3 087-088 C1 087-088
C3 089-090 C1 089-090
C3 091-092 C1 091-092
C3 093-094 C1 093-094
C3 095-096 C1 095-096
C3 097-098 C1 097-098
C3 099-100 C1 099-100
C3 101-102 C1 101-102
C3 103-104 C1 103-104
C3 105-106 C1 105-106
C3 107-108 C1 107-108
C3 109-110 C1 109-110
C3 111-112 C1 111-112